  •       It is a subsidiary of the device with a parallel between the engine , which can adjust the parameters to the unit's AC AC parameters are consistent with the external bus , so that the current generator can be successfully incorporated into the bus to go. Working principle : it contains portions of the phase angle difference , the synchronization detection section window range,...

Description
User manual:
Software Download:
Product:
Product description:

      It is a subsidiary of the device with a parallel between the engine , which can adjust the parameters to the unit's AC AC parameters are consistent with the external bus , so that the current generator can be successfully incorporated into the bus to go.

Working principle : it contains portions of the phase angle difference , the synchronization detection section window range , stable control of the engine speed and the gain adjustment section . When the detected current phase angle difference between the generator and the bus within a preset range of the output of a synchronous window relay signals to external devices and machines , if the phase angle difference is not within the range it will output an analog signal to the governor , a rapid change in engine speed , so that the phase angle difference is within the range , the synchronization process is completed . Under normal circumstances a good speed performance , and the car in less than 3 seconds .


Technical parameters:

Generators and electric discharge AC input sensitivity mother .............. 50VRMS-500mMS ( line to line or line to neutral )

Frequency ......................................... 5HZ or 60HZ

Isolated ......................................... 1000V min

Power consumption ....................................<2.5VA

DC supply requirements 8-10 Terminal

Low range ( shorted terminals 8 and 9 > ................ 10-16Vdc

High pressure range .................................. 14-40Vdc

Less than 200mA current demand ................................

Performance ( and ESD series controllers )

Capture range +4% in 3250HZ when ...............................

Output voltage .............................. 0.3-7Vdc

Closing angle range 1-25 degrees ...........................

Relay output capacity ......................... 10A at 28Vdc

Phase correction range ........................ + -10 degrees

Green diode ------ simultaneous display ...................

Red bus ..................................

Generators ............... , ............... red

DC supply ............................... red

Synchronizer two red for ............................

Together with the red relay ...........................

Environment

Temperature Range .............................-40F to 180F (-40C to +85 C)

....................................... 95% relative humidity

Shock ......................................... 5G (20-200b)